This free exponential distribution calculator finds P(X < x), P(X > x) or a probability between two times, plus the mean, standard deviation and median, from a rate λ or from the mean waiting time μ = 1/λ. It shows the step-by-step working with your numbers, a shaded density curve and the exact TI-84 e^ and LN keystrokes. The TI-84, TI-84 Plus CE and TI-83 Plus have no built-in exponpdf or exponcdf command, so the calculator writes the formula the way you enter it on the home screen. A percentile mode solves for the waiting time x with a given cumulative probability.
Contents
How to Use the Exponential Distribution Calculator
- Choose a parameter. Enter the rate λ (events per unit time) or switch to Mean and enter μ, the average waiting time. The two are reciprocals: μ = 1/λ.
- Pick the probability you need: P(X < x), P(X > x), P(a < X < b), or Find x (percentile) to solve for a waiting time from an area.
- Type x (or a and b, or the area p). Because the distribution is continuous, P(X < x) and P(X ≤ x) are the same, and P(X = x) is 0.
- Read the answer in the purple box, with the mean, standard deviation and median beside it. Open the step-by-step working and the TI-84 e^ keys written for your numbers.
Results update as you type. Copy share link saves your inputs in the URL. The Example button loads a classic waiting-time question: buses every 10 minutes on average, P(wait more than 15 minutes). If you are counting events in a fixed interval rather than waiting for the next one, use the Poisson calculator instead. The discrete analogue (trials until the first success) is the geometric distribution calculator.
What Is the Exponential Distribution?
The exponential distribution models the waiting time until the next event when events occur continuously and independently at a constant average rate. The time until the next phone call, the lifetime of a component that does not age, the wait for the next bus in a memoryless model, or the time between clicks on a Geiger counter are standard examples. We write X ~ Exponential(λ), with X ≥ 0.
Four things set this model apart:
- A constant rate λ (or equivalently a constant mean wait μ = 1/λ). The rate is how many events you expect per unit time, not a probability.
- A continuous waiting time. X can be any non-negative real number, so individual points have probability 0.
- The memoryless property. P(X > s + t | X > s) = P(X > t). The remaining wait does not depend on how long you have already waited. Among continuous distributions, only the exponential has this property.
- A link to the Poisson process. If the number of events in a fixed interval is Poisson with rate λ, the waiting time between events is exponential with the same λ.
Exponential Distribution Formulas
f(x) = λ e−λx for x ≥ 0 F(x) = P(X ≤ x) = 1 − e−λx
P(X > x) = e−λx P(a < X < b) = e−λa − e−λb
μ = σ = 1/λ Var(X) = 1/λ² median = ln(2)/λ
The mean and the standard deviation are the same number, 1/λ. The median is smaller, about 0.693/λ, because the right tail is long: a few very large waits pull the mean to the right of the typical wait. The percentile formula is the inverse of the cdf: x = −ln(1 − p)/λ. On a TI-84, ex is 2nd LN and the natural log is LN.
Worked Example: λ = 0.5, Wait Less Than 1 Minute
The calculator opens with this question: A service desk has an average wait of 2 minutes, so λ = 0.5. What is the probability that the next customer waits less than 1 minute?
- Less than 1 minute: P(X < 1) = 1 − e−0.5×1 = 1 − e−0.5 ≈ 0.3935.
- More than 1 minute: P(X > 1) = e−0.5 ≈ 0.6065. The two answers add to 1, as they must.
- Between 1 and 3 minutes: P(1 < X < 3) = e−0.5 − e−1.5 ≈ 0.6065 − 0.2231 = 0.3834.
- Mean, SD and median: μ = σ = 1/0.5 = 2 minutes, variance = 4, and the median is ln(2)/0.5 ≈ 1.3863 minutes.
On the TI-84, type 1-e^(-.5*1) and press ENTER to get ≈ .3935. The Example button loads a buses question: a bus every 10 minutes on average (μ = 10, so λ = 0.1) and P(wait more than 15 minutes) = e−1.5 ≈ 0.2231. The 50th percentile of the default distribution is the median, 1.3863, which you can also get from the Find x mode with p = 0.5.
Rate λ or Mean μ
Textbooks and software do not all parameterize the exponential the same way. Many intro stats books (and this calculator’s rate mode) use λ, the rate. Others, including some AP Statistics materials and R’s pexp, use the mean or scale θ = 1/λ. Entering the wrong one is a common source of answers that are off by a factor of the square of the mean.
Switch the calculator to Mean μ = 1/λ when the problem gives an average waiting time and never mentions λ. The steps then show λ = 1/μ before the probability is computed, so you can match either convention. For the default desk, μ = 2 and λ = 0.5 are the same model. For a mean of a random variable in general, not this waiting-time family, see the expected value calculator.
Exponential vs Poisson and Geometric
| Exponential | Poisson | Geometric | |
|---|---|---|---|
| What you measure | Waiting time until the next event | Number of events in a fixed interval | Trials until the first success |
| Type | Continuous, X ≥ 0 | Discrete counts 0, 1, 2, … | Discrete trials 1, 2, 3, … |
| Parameter | Rate λ or mean 1/λ | Mean λ (same rate, different use) | Success probability p |
| Memoryless? | Yes | Independent increments, not a wait | Yes (the discrete version) |
| TI-84 command | No built-in pdf; use e^ | poissonpdf and poissoncdf under DISTR | geometpdf and geometcdf under DISTR |
Use exponential for a waiting time, Poisson for a count in a window, and geometric for a sequence of independent Bernoulli trials. A normal approximation is a different model again; use the normal distribution calculator when a bell curve is the right shape, not a one-sided waiting time.
How to Calculate an Exponential Probability on a TI-84
Texas Instruments does not include exponpdf or exponcdf in the DISTR menu of the TI-84 Plus, TI-84 Plus CE or TI-83 Plus. You type the exponential formula on the home screen.
- For the default P(X < 1) with λ = 0.5 you want
1-e^(-.5*1). - Type 1 −, then press 2nd LN for e^(.
- Press (−) (the negate key, below 3, not the minus key), type .5 × 1, close the bracket and press ENTER. The calculator shows ≈ .3935.
- For P(X > 15) with mean 10, first get λ = 1/10 = 0.1, then type
e^(-.1*15), which returns ≈ .2231. - For a percentile, use LN: x = −ln(1 − p)/λ. For the median,
ln(2)/.5returns ≈ 1.3863.
Try every keystroke on our TI-84 Plus CE calculator online. All of the probability tools live on the math calculators hub.
Common Mistakes
- Looking for exponcdf on the TI-84. It is not in DISTR. Use 2nd LN for e^ and the formula 1 − e−λx.
- Mixing up λ and the mean. If the average wait is 10 minutes, λ is 0.1, not 10. Entering 10 as a rate makes every probability tiny.
- Using the minus key inside e^. The exponent needs the negate key (−). Minus often throws a syntax error or a wrong sign.
- Treating P(X = x) as a useful probability. For a continuous wait, that probability is 0. Use a range, or read the density f(x) as a height, not a chance.
- Using a normal or geometric model for a continuous wait. The bell curve is symmetric; the exponential is not. Geometric is counted in trials, not minutes.
- Forgetting memorylessness. “I have already waited 5 minutes, so the next 5 should be less likely” is false in this model. The remaining wait still has the same distribution.
Why This Exponential Calculator Is Different
- Rate or mean in the same tool, with the implied λ or μ shown in the steps so you can match either textbook convention.
- Honest TI-84 keystrokes. The calculator does not invent an exponcdf command. It writes 1−e^(−λx), e^(−λx) or −ln(1−p)/λ, including the negate key and LN vs 2nd LN.
- All three probability types (less than, more than, between) plus a percentile mode, with the mean, SD and median ln(2)/λ on the same screen.
- A shaded density curve marked with the mean, so you can see why the median sits left of the mean.
- Checked against exact arithmetic and SciPy on hundreds of random rates, including the default 0.3935 / 0.6065 example and the bus wait e−1.5 ≈ 0.2231. It works in dark mode, makes share links and fits a phone screen.
Exponential Distribution Calculator FAQ
TI 84 Calc PRO is not affiliated with or endorsed by Texas Instruments. TI-84 Plus CE is a trademark of Texas Instruments.
About this page